| - | The Kurobox [[case]] has a built in 40mm fan, which can run at variable speeds controlled through the [[microcontroller]]. | + | The Kurobox [[case]] has a built in 40mm fan, which can run at variable speeds controlled through the [[microcontroller]]. In this case the Kurobox has two fan speed presets-- slow or fast. |
The fan used in the Kurobox is a ADDA AD0412LX-G76 which measures 40mm x 40mm x 10mm. By looking at the model number, we can extract it's information: | The fan used in the Kurobox is a ADDA AD0412LX-G76 which measures 40mm x 40mm x 10mm. By looking at the model number, we can extract it's information: | ||
| Line 23: | Line 23: | ||
|} | |} | ||
''Source: [http://www.adda.com.tw/products/Fan%20numbering.gif ADDA Model Numbering Scheme]'' | ''Source: [http://www.adda.com.tw/products/Fan%20numbering.gif ADDA Model Numbering Scheme]'' | ||
| + | |||
| + | ==Fan Control== | ||
| + | There are some [[Fan Control|fan control]] scripts which will automatically set the fan speedbased on the current temperature of the [[Hard Drive]]. You can also manually set the speed from the Linux console. | ||
| + | |||
| + | Fast speed: | ||
| + | # /bin/echo -n ']]]]' > /dev/ttyS1 | ||
| + | Slow speed: | ||
| + | # /bin/echo -n '\\\\' > /dev/ttyS1 | ||
==Replacement== | ==Replacement== | ||
Revision as of 01:23, 2 August 2006
The Kurobox case has a built in 40mm fan, which can run at variable speeds controlled through the microcontroller. In this case the Kurobox has two fan speed presets-- slow or fast.
The fan used in the Kurobox is a ADDA AD0412LX-G76 which measures 40mm x 40mm x 10mm. By looking at the model number, we can extract it's information:
| AD | ADDA brushless DC fan |
| 04 | DC Frame size: 40mm |
| 12 | DC Voltage: 12VDC |
| L | Speed: Low |
| X | Bearing Type: HYPRO bearing |
| G | Thickness: 10mm |
| 7 | Impeller number: 7 blades |
| 6 | Motor protective circuit & Third lead wire: by transistor with speed sensor (FG) |
| [blank] | Fan type: Standard |
Source: ADDA Model Numbering Scheme
Fan Control
There are some fan control scripts which will automatically set the fan speedbased on the current temperature of the Hard Drive. You can also manually set the speed from the Linux console.
Fast speed:
# /bin/echo -n ']]]]' > /dev/ttyS1
Slow speed:
# /bin/echo -n '\\\\' > /dev/ttyS1
Replacement