Hardware LEDs
From NAS-Central Buffalo - The Linkstation Wiki
Revision as of 11:39, 17 May 2006 by 192.54.144.226 (Talk)
Contents |
LED Description
Power LED (green)
| on | Normal: Timed shutdown timer has not been activated |
| Blink | At bootup, prior to ppc_uartd starting, Just prior to flash memory being updated |
| Blink Slowly | Timeed shutdown has been established |
If ppc_uartd is not started for some reason (started late due to hardware/software issues), it remains blinking, and then after five minutes, DIAG LED blinks 6 times(hard disk error), 6 times, 6 times, ... finally the box shutsdown.
LINK/ACT LED
| orange | 10BASE-T |
| green | 100BASE-TX |
| blue | 1000BASE-T(only HGLAN) |
DISK FULL LED (red)
| on | Disk full |
| blink | Writing to flash memory |
DIAG LED (red)
| 3 times blink | Partition warning: /dev/hda3 is not mounted on /mnt. You can ignore it. |
| 4 times blink | Problem with the cooling fan - probably rotor jammed. |
| 5 times blink | Problem with the flash memory* |
| 6 times blink | Hard drive not found. Or ppc_uartd is not running. |
| 7 times blink | Problem with the RAM/LAN/HDD controller. |
| blink many times | Writing to flash memory. |
* Sometimes, you can recover from a flash memory error by pulling out power cord and try again after one night.
Table copied from http://www.yamasita.jp/linkstation.en/led.html with minor rewording. nobuakiy helped with the translation.
Notes Users have reported problems when the drive already has a Linux partition on it - the diag light blinks 6 times. The solution appears to be to simply to reformat the drive.