Power LED
| solid green | System on (normal). |
| blinks green | System booting (until ppc_uartd starts) or flash memory write in progress. |
| slowly blinks green | Sleep timer enabled. |
Link/Activity LED
| solid orange | 10Mbps connection. |
| solid green | 100Mbps connection. |
Disk Full LED
| solid red | Hard drive full. |
| blinks red | Flash memory write in progress. |
Diagnostic LED
| blinks red | Flash memory write in progress. |
| blinks red 3 times | /dev/hda3 not mounted to /mnt error (non-critical). |
| blinks red 4 times | Cooling fan error (critical, system shutdown). |
| blinks red 5 times | Flash memory error (critical, system powers off). |
| blinks red 6 times | Hard drive or ppc_uartd error (critical, system shutdown). |
| blinks red 7 times | RAM, NIC, or HDD controller error (critical, system shutdown). |
Most of this information courtesy of http://www.yamasita.jp/linkstation.en/index.html.