| - | == LED ERROR CODES ==
| |
| | | | |
| - | The Buffalo website suggest an alternate reading of the error codes.
| |
| - |
| |
| - | http://www.buffalotech.com/knowledgebase/users/kb.php?id=10011&category_id=0&sid2=
| |
| - |
| |
| - | LED Flash Code Explanation and solutions:
| |
| - |
| |
| - | The Info or Error light will flash a sequence of long flashes then a sequence of short flashes. The long flashes indicate the first number and the short flashes indicate the second number. For example: on the RED ERROR light, one long flash and five short flashes would be a disk error. On the ORANGE INFO light, two long flashes and seven short flashes indicate USB disk check.
| |
| - |
| |
| - | Info (orange) light:
| |
| - |
| |
| - | I10 - PCB overheat
| |
| - | I20 - internal HDD formatting
| |
| - | I21 - internal HDD checking
| |
| - | I22 - internal HDD recovering
| |
| - | I23 - System initialising
| |
| - | I25 - firmware updating
| |
| - | I26 - initialising web setting
| |
| - | I27 - USB disk checking
| |
| - | I28 - USB disk formatting
| |
| - | Error (red) light:
| |
| - |
| |
| - | E00 (no light, beep only) - MPU error
| |
| - | E01 - DRAM data line error
| |
| - | E02 - DRAM address line error
| |
| - | E03 - RTC chip error
| |
| - | E04 - flash error
| |
| - | E10 - UPS power loss
| |
| - | E11 - fan error (RPM too low or stopped altogether)
| |
| - | E12 - cooling error (unable to remove heat by the fan)
| |
| - | E15 - disk error
| |
| - | E16 - unable to locate internal HDD
| |
| - | E17 - unable to communicate with the RTC chip
| |
| - | E21 - unable to communicate with the Phy chip
| |
| - | E22 - mount error
| |