== LED ERROR CODES  ==
 
-
The Buffalo website suggest an alternate reading of the error codes.
 
-
 
-
http://www.buffalotech.com/knowledgebase/users/kb.php?id=10011&category_id=0&sid2=
 
-
 
-
LED Flash Code Explanation and solutions:
 
-
 
-
The Info or Error light will flash a sequence of long flashes then a sequence of short flashes. The long flashes indicate the first number and the short flashes indicate the second number.  For example: on the RED ERROR light, one long flash and five short flashes would be a disk error.  On the ORANGE INFO light, two long flashes and seven short flashes indicate USB disk check.
 
-
 
-
Info (orange) light:
 
-
 
-
I10 - PCB overheat
 
-
I20 - internal HDD formatting
 
-
I21 - internal HDD checking
 
-
I22 - internal HDD recovering
 
-
I23 - System initialising
 
-
I25 - firmware updating
 
-
I26 - initialising web setting
 
-
I27 - USB disk checking
 
-
I28 - USB disk formatting
 
-
Error (red) light:
 
-
 
-
E00 (no light, beep only) - MPU error
 
-
E01 - DRAM data line error
 
-
E02 - DRAM address line error
 
-
E03 - RTC chip error
 
-
E04 - flash error
 
-
E10 - UPS power loss
 
-
E11 - fan error (RPM too low or stopped altogether)
 
-
E12 - cooling error (unable to remove heat by the fan)
 
-
E15 - disk error
 
-
E16 - unable to locate internal HDD
 
-
E17 - unable to communicate with the RTC chip
 
-
E21 - unable to communicate with the Phy chip
 
-
E22 - mount error
 