Difference between revisions of "Talk:Information/PPCLED"

From NAS-Central Buffalo - The Linkstation Wiki
Jump to: navigation, search
(Removing all content from page)
Line 1: Line 1:
The Buffalo website suggest an alternate reading of the error codes.
LED Flash Code Explanation and solutions:
The Info or Error light will flash a sequence of long flashes then a sequence of short flashes. The long flashes indicate the first number and the short flashes indicate the second number.  For example: on the RED ERROR light, one long flash and five short flashes would be a disk error.  On the ORANGE INFO light, two long flashes and seven short flashes indicate USB disk check.
Info (orange) light:
I10 - PCB overheat
I20 - internal HDD formatting
I21 - internal HDD checking
I22 - internal HDD recovering
I23 - System initialising
I25 - firmware updating
I26 - initialising web setting
I27 - USB disk checking
I28 - USB disk formatting
Error (red) light:
E00 (no light, beep only) - MPU error
E01 - DRAM data line error
E02 - DRAM address line error
E03 - RTC chip error
E04 - flash error
E10 - UPS power loss
E11 - fan error (RPM too low or stopped altogether)
E12 - cooling error (unable to remove heat by the fan)
E15 - disk error
E16 - unable to locate internal HDD
E17 - unable to communicate with the RTC chip
E21 - unable to communicate with the Phy chip
E22 - mount error

Latest revision as of 12:37, 19 February 2008